JOB STORAGE AND RECALL
The current settings are automatically saved and will load next time the machine is used.
In addition to the current settings, it is possible to save and recall so-called «JOB» configurations.
There are 100 JOBS per welding process, the memorisation includes:
- The main parameter,
- The secondary parameter,
- Subprocesses and button modes.

JOB MODE

This mode allows you to create, save, recall and delete JOBs.
QUICK LOAD – Recall of the JOBs using the trigger when not welding.
The Quick Load is a JOB recall mode (20 max) excluding welding and possible only in MIG-MAG and TIG processes.
From a Quickload list of previously created JOBs, JOBs are recalled by pulling the trigger briefly. All trigger modes (2T/4T) and welding modes (SPOT/
STD/PLS) are supported.
TRIGGER FUNCTIONS
2T MODE
t
t
Trigger
Trigger
T1
T1
4T MODE
t
t
Trigger
T1
T2
Trigger
T1
T2
TORCHE IN OPTION
<0.5s
<0.5s
• Push-Pull Torch (4m : ref. 046283 / 6m : ref. 048713) :
The Push-Pull torch is mounted on the connector (FIG 1 - 9). This type of torch allows the use of AlSi wire even in Ø 0.8 mm with a 4 or 6 m long
torch. This torch can be used in all modes.
The detection of the Push-Pull torch is done by simply pulling the trigger.
t
If a potentiometer Push-Pull lamp is used, the setting on the interface is used to set the maximum value of the adjustment range.
t
The potentiometer then allows to vary between 50% and 100% of this value.
Bouton principal
T1
T2
Bouton principal
T1
T2
ou
ou
Bouton secondaire
Bouton secondaire
Connection diagram for Push Pull torch
with potentiometer (10 KΩ)
PULSEMIG 220 C / 220 C XL
t
t
T2
T2
t
t
T4
T3
T4
T3
<0.5s
>0.5s
<0.5s
>0.5s
t
t
T4
T3
T4
T3
T1 - The trigger is pulled, the welding cycle starts (PreGas, I_Start,
UpSlope and welding).
T2 - The trigger released, the welding cycle stops (DownSlope,
I_Stop, PostGaz).
T1 - The trigger is pulled, the cycle starts from the PreGas and
stops in the I_Start phase.
T2 - The trigger is released, the cycle continues in UpSlope and
welding.
T3 - The trigger is pulled, the cycle switches to DownSlope and
stops in the I_Stop phase.