Specifications For Ebro And Ebro-R; External Cleaning; Seasonal Stoppages; Troubleshooting Guide - Bronpi LORCA-C Insrucciones De Instalacion Y Del Operador

Ocultar thumbs Ver también para LORCA-C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9.4.

SPECIFICATIONS FOR EBRO AND EBRO-R

Over time and with the use, the fireplaces with oven can create soot deposits
in the external parts of the oven. These deposits can obstruct the draw and
cause a malfunction of the fireplace. For this reason, it is important to remove
them through a register that is hidden under the logo of the oven door. It is
necessary to unscrew the logo and use the hole in order to proceed with the
cleaning (see drawing D35).
When you are cleaning the oven, please be careful and do not
use aggressive products because they can wear down the paint
and too much water can oxidise it.
9.5.

EXTERNAL CLEANING

Do not clean the external surface of the fireplace with water or abrasive products because they may damage the fireplace.
Use a feather duster or a rag a bit wet.

10. SEASONAL STOPPAGES

After cleaning the chimney and the fireplace by removing the ash and other residues, close all doors and regulators.
It is recommended to clean the chimney at least once a year. Meanwhile, check the joints because if they are not in good condition (they do
not adjust to the door), they do not guarantee the proper operation of the fireplace! For this reason, it would be necessary to change them.
You can find this spare part in the same Bronpi distributor where you bought your fireplace.
If there is humidity in the place where the fireplace is installed, put absorbent salts inside the equipment. Protect the internal parts with neutral
vaseline in order to keep the appearance along the time.

11. TROUBLESHOOTING GUIDE

PROBLEM
POSSIBLE REASON
The fireplace
Inappropriate use of the fireplace
gives off smoke
Smoke duct is cold
Smoke duct is obstructed
Smoke duct is oversized
Smoke duct is tight
The draw is not enough
Smoke duct with infiltrations
More than one equipment connected to the
duct
Air returns
Inappropriate use of the fireplace
Combustion range too low. Lack of draw
Excessive ash accumulation
The smoke duct does not protrude the top
of the roof
Combustion out
The door is not sealed properly or is open
of control
Excessive draw
Refractory sealing plaster is damaged
Smoke duct is oversized
Strong winds
Green or wet wood with bad quality
Insufficient heat
Green or wet wood with bad quality
Lack of primary air
Smoke duct with air infiltrations
Masonry exterior of the chimney is cold
Heat loss in the house
** The note PROFES means that the task must be done by a professional.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
SOLUTION
Open the primary air intake a few minutes and then open
the door
Pre-heat the fireplace
Check the duct and the connector to see if it is obstructed or
has excessive soot
Install an appropriate diameter
Install an appropriate diameter
Add length to the chimney
Seal connections between sections
Disconnect the rest of equipments and seal the entrances
Open completely the primary air intake and, later, the door
during a few minutes
Use the fireplace with an appropriate range. Increase the
primary air intake
Empty the ash pan frequently
Add length to the chimney
Close the door or change the sealing cords
Check the installation or install a draft-diverter valve
Check the joints and use refractory putty
Install an appropriate diameter
Install an appropriate chimney cowl
Use dry wood. Air dried during at least 1 year
Use dry wood. Air dried during at least 2 years
Increase the primary air intake
Use an insulated system of chimney
Insulate thermally the chimney
Seal windows, openings, etc
Table 2
24
D35
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
PROFES
METALLIC FIREPLACES

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

EbroEbro-rFlorenciaManhattan

Tabla de contenido