System cleaning programs
F2. SYSTEM CLEANING
The first stage of this program cleans the system with a citric acid solution. The second
stage runs water through the system to rinse the pipes.
Make a solution of 16 g citric
acid and 200 g of water, add the
solution to the water tank. Ensure
drip tray is empty.
After the program has paused,
empty the drip tray and fill the
water tank with water (to max
level).
Note
1.
SYSTEM CLEANING program.
2. If the SYSTEM CLEANING program is not used regularly, the pipe will get
blocked and the steaming performance will be less effective.
3. Do not remove the drip tray during the DRAIN WATER program.
4. Empty the drip tray and rinse with running tap water after the program has
finished.
58
EN
Tap System Cleaning twice
until "F2 SYSTEM CLEANING"
program appears in the display.
Touch Start. The program will run
for approx. 1 minute. Empty the
drip tray after the program has
finished.
symbol appears in the display when running the DRAIN WATER and
Touch Start. The
program will
run for approx.
29 minutes.