4 Installation (Continued)
4.2 Connecting Air Line / Reference – Figure 1
®
Loctite
Shot Miser
•
Connect foot pedal, as shown in Figure 1, to the valve controller.
•
Connect 4mm airline from the normally not passing port, first the air line connection from
front of controller, then to the air cylinder on the dispense valve.
•
Insure that normally passing port has port plug installed (second airline connection from front
of controller).
•
Connect supply air to 'Air In Port' on valve controller.
•
Connect supply air to 'Air In Port' on reservoir.
4.3 Product Supply Tube
Note that this is a Teflon® lined tube.
Slide the nut and ferrule onto the product supply tube.
Push the end of the product supply tube into the Vari-Drop™. Make sure the end of the product
supply tube bottoms in the Vari-Drop™.
Position the nut and ferrule and tighten the fitting nut 1 to 1½ turns past finger tight.
Connect the other end of the product supply tube to the product pressure reservoir as stated in
'Install Anti-Bubbler'.
4.4 Installing the Anti–Bubbler to .5 liter and 2 liter Reservoirs
Anti-Bubbler
The anti-bubbler is inserted at the end of the product supply tube that resides in the product reservoir. The
purpose of the anti-bubbler is to minimize the amount of adhesive that will run out of the product supply
tube when the reservoir lid is removed to re-fill the product reservoir.
A. Anti-Bubbler Installation – ¼ inch tubing
Install the spring guard, the fitting nut, and the ferrule onto the feed line. Insert feed line into the fitting
located in the reservoir lid. Insert the anti – bubbler into anti-bubbler connection sleeve. Push anti-bubbler
connection sleeve onto 1/4 inch feed line. Position the feed line so that the anti-bubbler is close to the
bottom of the adhesive bottle.
F e e d lin e to V a lv e
TM
Dispense System
C o n n e c tio n S le e v e
A d a p te r