Description (Continued)
Timed
Regulado
E
POWER
OUT
0.6
MODE
Shot Miser™
0.4
0.8
0.2
1.0
Valve Controller
Controlador De Válvula
0
1.2
sec
# 98079
Manual
OMRON H3CR
Dispense Time
Tiempo De Dosificación
2.2 Theory of Operation
®
The Loctite
Shot Miser
•
Product under pressure is supplied from a reservoir to the fluid inlet of the dispense valve.
•
An air signal is supplied from valve controller to the air cylinder of the dispense valve.
•
The air cylinder operates the Vari-Drop™ lever, opening the pinch tube.
•
Product flows out of the dispense needle.
•
The control timer times out.
•
The air cylinder rod retracts.
•
The pinch tube closes and the product flow stops.
The amount of product dispensed is controlled by:
•
The reservoir pressure.
•
The time the pinch valve is open.
•
The dispense tip I.D.
•
The amount that the pinch valve opens.