Description (Continued)
Timed
Regulado
E
POWER
OUT
0.6
MODE
Shot Miser™
0.4
0.8
0.2
1.0
Valve Controller
Controlador De Válvula
0
1.2
sec
# 98079
Manual
OMRON H3CR
Dispense Time
Tiempo De Dosificación

2.2 Theory of Operation

®
The Loctite
Shot Miser
Product under pressure is supplied from a reservoir to the fluid inlet of the dispense valve.
An air signal is supplied from valve controller to the air cylinder of the dispense valve.
The air cylinder operates the Vari-Drop™ lever, opening the pinch tube.
Product flows out of the dispense needle.
The control timer times out.
The air cylinder rod retracts.
The pinch tube closes and the product flow stops.
The amount of product dispensed is controlled by:
The reservoir pressure.
The time the pinch valve is open.
The dispense tip I.D.
The amount that the pinch valve opens.
POWER
OUT
0.6
0.4
0.8
0.2
1.0
0
1.2
sec
OMRON H3CR
Figure 4 Valve Controller Assembly
TM
Dispense System operates as follows:
E
MODE
o
I
Warning: Electrical Hazard Disconnect
Power Cord Before Removing Cover.
Advertencia: Peligro eléctrico
Desconecte el cable eléctrico antes de
quitar la cubierta.
115 VAC, 50/60 Hz.
Fuses/Fusibles: 1A, 5mm x 20mm