Sound Pressure Level; Electrical Data; Ar Control Unit; Power Supply - Grundfos DMH 25X Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 148
Maximum suction lift (continuous operation) for media with
maximum permissible viscosity
Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257

3.5 Sound pressure level

Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
* Testing according to DIN 45635-01-KL3.

3.6 Electrical data

3.6.1 Enclosure class
The enclosure class depends on the motor variant selected, see
motor nameplate.
The specified enclosure class can only be ensured if the power
supply cable is connected with the same degree of protection.
Pumps with electronics: The enclosure class is only met if the
sockets are protected! The data regarding the enclosure class
applies to pumps with correctly inserted plugs or screwed-on
caps.
3.6.2 Motor
Version: see motor and pump nameplates.

3.7 AR control unit

Functions of pumps with electronics:
"Continuous operation" button for function test and dosing
head deaeration
memory function (stores a maximum of 65,000 pulses)
two-stage tank-empty signal (e.g. via Grundfos tank empty
sensor)
stroke signal/pre-empty signal (adjustable), e.g. as a feedback
to the control room
dosing controller function (only with sensor - optional)
diaphragm leakage detection (only with sensor - optional)
access-code-protected settings
remote on/off
Hall sensor
operating hours counter
motor monitoring.
Operating modes:
manual
Stroke frequency: manually adjustable between zero and
maximum
contact signal control
Multiplier (1:n) and divisor (n:1)
current signal control 0-20 mA/4-20 mA
Adjustment of stroke frequency proportional to the current
signal. Weighting of current input.
12
Maximum suction lift
[m WC]
Flooded suction
Flooded suction
Flooded suction
Flooded suction
Flooded suction
Flooded suction
55 ± 5 dB(A)*
55 ± 5 dB(A)*
65 ± 5 dB(A)*
65 ± 5 dB(A)*
75 ± 5 dB(A)*
75 ± 5 dB(A)*
3.7.1 Inputs and outputs
Inputs
Contact signal
Current 0-20 mA
Remote on/off
Two-stage tank-empty signal
Dosing controller and diaphragm leakage sensor
Outputs
Current 0-20 mA
Error signal
Stroke signal
Pre-empty signal
AR control unit factory settings
Inputs and outputs: NO (normally open)
or
inputs and outputs: NC (normally closed).

3.8 Power supply

Power supply for AC voltage
Permissible deviation from rated
Rated voltage
230 / 400 V
240 / 415 V
115 V
Maximum permissible mains impedance
(0.084 + j 0.084) Ohm (testing according to DIN EN 61000-3-11).
These details apply to 50 Hz.

3.9 Ambient and operating conditions

Permissible air humidity: max. relative humidity:
70 % at +40 °C, 90 % at +35 °C.
The installation site must be under cover!
Caution
Do not install outdoors!
3.9.1 DMH with motor labelled for coolant temperature -20 °C
≤ T
≤ 40 °C
amb
Permissible ambient temperature: 0 °C (standard) to +40 °C
(for an installation height up to 1000 m above sea level)
Pumps with minimum T
amb
Permissible storage temperature: -20 °C to +50 °C.
3.9.2 DMH with motor labelled for coolant temperature -20 °C
≤ T
≤ 55 °C and with dosing head material
amb
stainless steel or PVDF
Permissible ambient temperature: 0 °C (standard) to +55 °C
(for an installation height up to 1000 m above sea level)
Pumps with minimum T
amb
Permissible storage temperature: -20 °C to +55 °C.
Note
Observe the nameplate of the motor.
Maximum load: 12 V, 5 mA
Maximum load: 22 Ω
Maximum load: 12 V, 5 mA
Maximum load: 12 V, 5 mA
Maximum load: 350 Ω
Maximum ohmic load:
50 VDC/75 VAC, 0.5 A
Contact time/stroke: 200 ms
Maximum ohmic load:
50 VDC/75 VAC, 0.5 A
value
± 10 %
± 10 %
± 10 %
-20 °C available on request
-20 °C available on request

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dmh 1150-10

Tabla de contenido