Inlet Pressure And Counter-Pressure/Suction Lift - Grundfos DMH 25X Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 148
Pump type
Single pump
Double pump
DMH 254
DMH 50-10
DMH 50-10/50-10
DMH 102-10
DMH 102-10/102-10
DMH 143-10
DMH 143-10/143-10
DMH 175-10
DMH 175-10/175-10
DMH 213-10
DMH 213-10/213-10
DMH 291-10
DMH 291-10/291-10
DMH 46-16
DMH 46-16/46-16
DMH 97-16
DMH 97-16/97-16
DMH 136-16
DMH 136-16/136-16
DMH 166-16
DMH 166-16/166-16
DMH 202-16
DMH 202-16/202-16
DMH 276-16
DMH 276-16/276-16
DMH 255
DMH 194-10
DMH 194-10/194-10
DMH 270-10
DMH 270-10/270-10
DMH 332-10
DMH 332-10/332-10
DMH 403-10
DMH 403-10/403-10
DMH 550-10
DMH 550-10/550-10
DMH 257
DMH 220-10
DMH 220-10/220-10
DMH 440-10
DMH 440-10/440-10
DMH 575-10
DMH 575-10/575-10
DMH 750-4
DMH 750-4/750-4
DMH 770-10
DMH 770-10/770-10
DMH 880-10
DMH 880-10/880-10
DMH 1150-10
DMH 1150-10/1150-10
DMH 1500-4
DMH 1500-4/1500-4
* l/h per dosing head; double the capacity for double pumps.
The pump can be operated in the range between 10
Note
% and 100 % of the maximum dosing capacity.
3.4.1 Accuracy
Dosing flow fluctuation: smaller than ± 1.5 % within the control
range 10-100 %
Linearity deviation: ± 2 % of the full-scale value.
Applies to:
water as dosing medium
fully deaerated dosing head
standard pump version.

3.4.2 Inlet pressure and counter-pressure/suction lift

Maximum inlet pressure
Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
10
50 Hz
Max.
Q*
p max.
stroke
rate
[l/h]
[bar]
[n/min]
50
10
26
102
10
54
143
10
75
175
10
92
213
10
112
291
10
153
46
16
26
97
16
54
136
16
75
166
16
92
202
16
112
276
16
153
194
10
54
270
10
75
332
10
92
403
10
112
550
10
153
220
10
28
440
10
56
575
10
73
750
4
73
770
10
98
880
10
112
1150
10
146
1500
4
146
Minimum counter-pressure at the discharge valve of the
pump
Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
[bar]
Note
8
8
5
5
0.8
0.8
60 Hz
Max.
Q*
p max.
stroke
Q*
rate
[l/h]
[bar]
[n/min]
[l/h]
60
10
31
101
122
10
65
203
172
10
90
286
210
10
110
255
10
134
-
-
-
55
16
31
92
116
16
65
193
163
16
90
271
200
16
110
242
16
134
-
-
-
233
10
65
387
324
10
90
540
398
10
110
484
10
134
-
-
-
264
10
34
440
528
10
67
880
690
10
88
1150
900
4
88
1500
924
10
118
1056
10
134
-
-
-
-
-
-
A positive pressure difference of at least 2 bar is
required between the suction valve and the
discharge valve in order for the dosing pump to
operate correctly.
If the total counter-pressure (at the dosing point) and
geodetic height difference between the suction valve
and the dosing point is less than 2 bar (20 m WC), a
pressure-loading valve must be installed immediately
before the dosing point.
100 Hz
Max.
p max.
stroke
rate
[bar]
[n/min]
10
52
10
108
10
150
-
-
-
-
-
-
-
-
-
16
52
16
108
16
150
-
-
-
-
-
-
-
-
-
10
108
10
150
-
-
-
-
-
-
-
-
-
10
56
10
112
10
146
4
146
-
-
-
-
-
-
-
-
-
-
-
-
[bar]
2
2
2
2
2
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dmh 1150-10

Tabla de contenido