3 -Connect the cable to terminals (G) (230V live and earth) on the panelboard.
4 -Connect cable (H) powering the control panel to the socket (L).
GB
5 -Connect the battery as indicated in the following paragraphs.
6 -Close the door (E) when the operation has been completed.
Important
Only connect the battery after having made all the electrical connections.
CONNECTING THE BATTERY CHARGER
– The unit is set up to provide for automatic battery recharging. If this function is to be used,
proceed as follows.
– Choose the cables of the correct section (see "Technical data").
– Connect the electric cable to the positive pole of the battery to be charged. If the battery to
be charged is not the one used to start the generator, the negative terminal of that battery
must be connected to the generator mass point.
(G)
Clamps
(L)
(H)
Socket
Cable
Battery +
Battery -
Clamps
Battery charger
- 26 -
Use, maintenance and installation instructions
TEC 30D EV
(G)
Fuel reserve indicator