Plumbing connections (by the Dealer)
YOUR STOVE MUST NEVER BE ALLOWED TO FUNCTION WITHOUT ANY WATER IN THE SYSTEM.
IF YOU EVER LIGHT YOUR STOVE UP WHEN IT IS DRY, YOU WILL DAMAGE IT.
The plumbing connections must be made by qualified staff entitled to issue a declaration of compliance with Italian Law MD 37, ex
L 46/90 or the equivalent laws in force in the case of foreign countries.
Practical NOTE
When connecting the water supply, return and overflow pipes, provide solutions suitable for making it easy to move the stove in futu-
re, if and when the need arises.
Treating the water
You should make provision for antifreeze, anti-incrustation and anti-corrosion substances to be added to the water. If the water used
to fill and top up the system has a hardness in excess of 35°F, you should also use a water softener to reduce its hardness.
For suggestions, refer to UNI standard 8065-1989 (Treating water in heating systems for residential use) or your national equivalent.
Observation of return water temperature.
A suitable system must be provided for to guarantee a return water temperature of no lower than 45°C.
Here are some examples of possible system layouts.
System as the sole source of heating.
This layout is indicative only: your plumber will be responsible for the ultimate installation.
System for heating combined with a water boiler.
This layout is indicative only: your plumber will be responsible for the ultimate installation.
03/07/2009
12.24
Pagina 29
LEGEND
AF: Cold water
AL: Water supply input
C:
GR: Pressure reducer
MI: System in
P:
RA: Radiators
RI:
S:
ST:
TS: Stove
V:
VA: Automatic air vent
Vec: Closed surge tank
VSP: Safety valve
VST: Thermal discharge valve
LEGEND
ACS: Household hot water
AF:
AL:
C:
GR:
MI:
P:
RA:
RI:
S:
SB:
ST:
TS:
V:
VA:
Vec:
VSP: Safety valve
VST: Thermal discharge valve
28
Fill/Top up
Pump (circulation)
System return
Drain
Temperature probe
Spherical valve
Cold water
Water supply input
Fill/Top up
Pressure reducer
System in
Pump (circulation)
Radiators
System return
Drain
Water boiler
Temperature probe
Stove
Spherical valve
Automatic air vent
Closed surge tank