8 | Setup and installation
Fig. 6: Exhaust air rail (1)
Installation and removal of display
shelves
Responsibility
– Operating company
Display shelves are installed on delivery.
Remove the display shelves and brackets for reposi-
tioning and cleaning purposes.
CAUTION
Improper installation of the display
shelves.
Risk of injury due to falling of the display
shelves holding goods.
§ The brackets for display shelves must
snap completely into the openings
provided when being attached.
§ Only use tilted display shelves with a
goods stopper.
NOTICE
Material damage due to deformation of the
display shelves.
§ Attach the brackets in parallel and at the same
height.
Display shelves can be installed in both flat and tilted
positions.
Bracket attachment positions
a) Attach the brackets for the display shelves to the
openings in the rear panel.
2
Fig. 7: Bracket (1) attachment positions for flat (2) and tilted
(3) display shelf
Optional accessories
– Goods stopper
– Goods separator
– Side water protection strips
– With LISBOA 250
38 / 500
1
3
1
Installing the goods stopper and goods
separator
a) Insert the goods stopper/goods separator into the
designated groove.
3
1
2
Fig. 8: Display shelf with goods stopper (1), groove (2) and
goods separator (3)
Installing the side water protection strips
Responsibility
– Qualified staff
8.1
Electrical connection
The connection to the power supply is made by
trained personnel.
Technical data [see } Chapter 3.2]
WARNING
Connect the appliance to the power
supply.
Contact with live parts may result in electric
shock. Fire hazard due to sparking or over-
load.
§ Only qualified staff may carry out work on
the electrical system.
§ Note and adhere to the following before
connecting to the power supply:
- Applicable local electrical safety regula-
tions.
- Applicable standards and safety instruc-
tions.
- Information on rating plate
[see } Chapter 3.2.1].
§ Do not connect a damaged appliance or
damaged parts (such as connecting
cables) to the power supply.
§ Only qualified staff may replace damaged
parts, e.g. connecting cables.
§ Do not squeeze or bend connecting
cables.
§ Adhere to the minimum requirements for
connecting cables [see } Chapter 3.2].
§ Fuse the appliance in accordance with the
applicable regulations and laws as well as
the specifications issued by AHT
[see } Chapter 8.2].
§ Only connect the appliance to a mains cir-
cuit with protective earthing.
AHT Cooling Systems GmbH | en
416433_1_0720