11 | Maintenance

Longer shutdown
a) Carry out the steps for shutdown
b) Perform basic cleaning [see } Chapter 11.1.1].
c) Leave the doors open.
NOTICE
Material damage during prolonged shutdown.
§ Do not expose the appliance to heat radiation.
§ Do not place anything in or on the appliance.
§ Store the appliance in a stable operating position
(horizontal alignment).

10.2.2 Restart

Restarting is the same as regular start-up
[see } Chapter 9].
10.3

Malfunction during operation

NOTICE
Material and property damage in the event of
an alarm display.
§ Move the goods to another appliance with the
same product temperature class.
§ Contact the maintenance service immediately
[see } Chapter 12.4].
Display of alarms
There are different types of alarms that indicate mal-
functions during operation.
– Display operating element [see } Chapter 5.2]
– Error code
– Alarm indicator symbol
Error codes may be output via a store monitoring sys-
tem.
Further remote monitoring options can be obtained
from your maintenance service [see } Chapter 12.4].
11
Maintenance
Inspection tasks by operating personnel
Control tasks
quency
Proper condition of
ongoing
appliances
Foreign objects in
ongoing
goods area
Function of soft-
ongoing
close mechanism
Closed doors
ongoing
Damage glass ele-
ongoing
ments /doors
Breakage of stored
ongoing
glass containers
42 / 500
Fre-
description
[see } Chapter 2.2]
[see } Chapter 10]
[see } Chapter 2.2]
[see } Chapter 10]
[see } Chapter 4]
[see } Chapter 2.2]
[see } Chapter 2.5.3]
[see } Chapter 2.5.3]
[see } Chapter 10]
[see } Chapter 2.5.3]
[see } Chapter 10]
Control tasks
quency
Proper loading with
ongoing
goods
several
Interior temperature
times a
day
Contamination of the
appliance, including
daily
glass
Food and packaging
daily
residues
Puddles in front of/
underneath appli-
daily
ance (defrosting/
condensation water)
Floor (surroundings
daily
of the appliance)
Base tray/collecting
Weekly
trays
WARNING
Electrostatic discharge and spark
formation with flammable refrigerant.
On a damaged / leaking refrigerant circuit,
sparks may ignite escaping refrigerant. Fire
hazard.
§ Use a damp cloth or sponge to remove
condensation water.
§ Do not use dry cloths or sponges to dry
the appliance.
§ Do not operate any electrical devices (e.g.
wet vacuum cleaners) inside the cooling
compartment that do not correspond to
the design recommended by the manufac-
turer. Appliances with explosion protection
markings [see } Chapter 2.1] are permit-
ted.
11.1

Cleaning

Reasons for regular and thorough cleaning (basic
cleaning/main cleaning):
– Ensuring the necessary hygiene. Always keep the
goods area in a clean condition.
– Lowest possible energy consumption.
– Maintaining trouble-free operation.
– Extension of the service life of the appliance.
WARNING
Damage to the electrical system and
refrigerant circuit due to the use of
steam and high-pressure cleaners.
AHT Cooling Systems GmbH | en
Fre-
description
[see } Chapter 10.1]
[see } Chapter 5.1]
[see } Chapter 11.1.1
]
[see } Chapter 11.1.1
]
[see } Chapter 4.1]
[see } Chapter 10]
[see } Chapter 11.1.1
]
[see } Chapter 11.1.1
]
416433_1_0720

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aht lisboa 250Aht lisboa ec

Tabla de contenido