POSSIBLE TROUBLESHOOTING
POSSIBLE TROUBLESHOOTING
AL 11 Stop/Flame: (this occurs if the fume probe detects a fume temperature lower than the set value and inter
7) Signalling:
Problem:
Turns off due to drop in smoke temperature
Flame may fail for any of the following reasons:
- lack of pellets
Actions:
- too many pellets have suffocated the fl ame, check pellet quality (DEALER)
• Check whether the maximum thermostat has caused the problem (rare circumstance since this would
correspond to over heated fumes (technical assistance centre)
• Check whether the pressure switch has cut off electricity to the gear motor because of a blocked fl ue or other
problem.
AL 13 over heated fumes (turns off due to exceeding maximum smoke temperature).
8) Signalling:
Problem:
Switches off because of overheated fumes.
Over heated fumes may depend on: type of pellets, anomalous fume extraction, blocked channel, incorrect
installation, gear motor drift, lack of air vents in the room.
AL 14 Overheating of the electronic control board (this occurs if the temperature of the electronic board is
9) Signalling:
higher than 70°C)
Problem:
Shutdown due to exceeding maximum temperature of electronic control board.
Check the functionality of the room fan, and motor (DEALER)
Actions:
• Check the operation of the electronic control board (DEALER)
10) Signalling: BOUT black out stop (not a defect of the stove).
Turns off due to lack of electricity
Problem:
• Check electricity connection and drops in voltage.
Actions:
prets this as the absence of fl ames)