To be integrated with a complete reading of the technical specifi cations
Positioning and installing
First ignition performed by authorised CAT who released the guarantee certifi cate
Air vent in the room
Only the stove outlet passes through the smoke channel/chimney fl ue
Features of the smoke channel (stretch of duct connecting the stove to the fl ue/chimney):
Chimney pot that is high enough to avoid downdraft areas
The discharge pipes are made of a suitable material (stainless steel is recommended)
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
Use
Good quality, dry pellets are used
The chimney pot and ash compartment are clean and well positioned
The door is closed properly
The combustion chamber is inserted properly into the relevant compartment
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
TELEPHONE DIALLER FOR REMOTE IGNITION
The stove can be ignited remotely by asking the DEALER to connect the telephone combiner to the serial port behind the stove via the
optional cable.

• REMOTE CONTROL

• KIT 12 to channel hot air to an adjacent room
• KIT 12 Bis to channel hot air to a remote room
GlassKamin
Used for cleaning the
ceramic glass

CHECK LIST

a maximum of 3 curves,
a maximum 2 horizontal metres
OPTIONAL

CLEANING ACCESSORIES

- 52
-
Ash vacuum cleaner
User for cleaning the hearth