UL Presriptions
The motor out field wiring cable are able to be up to max. 18AWG
External recommended breaking resistor: R/C (NMTR2,NMTR8) Min. 100Ohm, Min.
Power 100W and Duty Cycle minor than 50%.
The date of manufacture is printed on the label.
Main Input:
! ECO TECH X 410: 230-480Vac, 50/60 Hz, 3 phases, 3.0 Aac.
! ECO TECH X 512: 230-480Vac, 50/60 Hz, 3 phases, 3.8 Aac.
! ECO TECH X 615: 230-480Vac, 50/60 Hz, 3 phases, 4.5 Aac.
Main Output:
! ECO TECH X 410: 0-330Vac at 480Vac of input, 4 Arms, 0-300Hz, 2.2 Kw, 3
phases.
! ECO TECH X 512: 0-330Vac at 480Vac of input, 5 Arms, 0-300Hz, 2.7 Kw, 3
phases.
! ECO TECH X 615: 0-330Vac at 480Vac of input, 6 Arms, 0-300Hz, 3.3 Kw, 3
phases.
Options available for the model UL:
! STO
! Resolver
! Resolver to encoder
!
BiSS
ESA elettronica S.p.A.
Unità Locale di Bentivoglio
Via Monari Sardè, 3
40010 Bentivoglio (BO) ITALY
Tel. ++39.0516640464
Fax ++39.0516640784
Web:
www.esa-automation.com
E-mail:
customer.care@esa-automation.com