Basic Operation
5
6
On/Off
Characteristics of Heat Mode
The system automatically controls the following operating modes to
prevent the reduction of heating capacity and space comfort.
Defrost operation
Hot start
12
Adjust Airfl ow Direction from the main menu
.
(see page 23)
*
If the connected indoor unit does not have oscillating louvers,
this function will not be available.
When
On/Off button is pressed again,
the system will stop operating and the
Operation lamp will turn off.
*
When the system is stopped while in the heating
mode, the fan will continue to operate for
approximately one minute to remove residual
heat from the indoor unit.
Note
To prevent condensation water damage or system failure, do not
shut off the power supply to the indoor unit immediately after
operation. Wait at least fi ve minutes for the condensate pump to
fi nish draining residual water from the indoor unit.
The system will automatically go into defrost operation to prevent frost
accumulation at the outdoor unit and subsequent loss of heating
capacity.
The indoor unit fan will stop, and "
remote controller.
The system will fi nish the Defrost operation and return to normal
usually within six to eight minutes. It won't last for more than ten
minutes.
When the system starts heating operation, the indoor unit fan will
operate with a delay in order to prevent a cold draft.
(In that case, " STANDBY " will be displayed on the remote controller.)
STANDBY " will be displayed on the