Beta 1852 R1750 Manual De Instrucciones página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
INSTRUCTIONS FOR USE
ISTRUZIONI PER L'USO
FLEXIBLE COIL
The flexible coil is used to loosen axle filaments, stiffened sensors, ball joints etc., and in applications where attachable coils
cannot be used.
Applications:
1. Connect one end of the coil to the coil holder, and secure it by the locking screw.
2. Wrap the free end of the conductor over the part which needs to be heated. Make around 2-4 turns.
3. Connect the second free end of the coil into the coil holder, and secure it by the locking screw.
4. Pressing of the key activates heating.
5. After finishing heating, one end of the coil will be released, and the coil will be unwound from the heated material.
If the device gets overheated (the LED warning light on the front panel is flashing red), unwind one loop and repeat
the procedure until the heating is carried out without overload and turning off.
On the contrary, if the heating has a low intensity, try adding one loop.
DEVICE INDICATORS
Lights on the device indicate the following states:
• Green
- Standby
• Yellow
- Heating in progress
• Yellow flashing
- Device is overheated
• Red flashing
- Bad coil or power overload
• Red light
- Error
POSSIBLE PROBLEMS AND TROUBLESHOOTING
1. The induction heater BETA 1852 is designed and constructed so that when an overload occurs, there is a temporary turning
off, which is indicated by the flashing of the LED on the front panel.
2. The induction coils do not have any thermal protection, and thus they are not protected against overload. The operating cycle
of the induction coils is set for 2 minutes of heating and 2 minutes of cooling.
3. If the device stops working, check that it is properly connected to the electric network and also check the plug connector and
socket, the fuses or breaker. Check the value of the supplied network current. Also make sure that the incoming and connection
cable (if you use it) is not damaged. Let the device cool off for at least 10 minutes, and then reconnect it. If the problem persists,
please contact your supplier.
4. Using an inappropriate extension cable (too long, small diameter of wires) can cause insufficient power of the device – see
the safety regulations.
5. In case other problems should occur, please contact your supplier.
EN
I
17

Publicidad

Tabla de contenido
loading

Tabla de contenido