Using the menu structure
There are three view types:
● Operation view
The operator view shows up to six operation views. The operation views are fully configurable to show different process
values in different operation view types. Depending on the operation view type configuration the view is either
measurement view or alarm view.
–
Measurement view: Displays the measurement values.
–
Alarm view: Displays the active alarms in a list.
–
Operating view: Enables the totalizer reset and the dosing control.
–
Diagnostic view: Displays six configurable measurement/diagnostic values.
● Navigation view
The navigation view shows the menus and parameters. The navigation view is used to navigate to the menus and
parameters in the device.
● Parameter view
The parameter view can be entered form the navigation view. The parameter view is used to view and edit the
parameters.
Navigating the views
Browse the views and menu items using the control buttons as follows:
Table 5-1
Measurement view
Key
Function
No functionality
Go to the previous menu in the operation view
Go to the next menu in the operation view
Enter the navigation view
Table 5-2
Parameter edit view
Key
Function
Select the next left position.
If the most left position is selected, exit the parameter edit view without confirming the changes. Keep
pressing the key to jump to the most left position.
Change the selected number/character.
Numeric characters: increase the number by one (for example from 7 to 8)
ASCII characters: select the previous character in the alphabet.
Change the selected number/character.
Numeric characters: decrease the number by one (for example from 8 to 7)
ASCII characters: select the next character in the alphabet.
Select the next right position.
If most right position is selected, confirm the change and exit the parameter edit view. Keep pressing the
key to jump to the most right position.
FCT030 transmitter
A5E03650800-AH, 05/2015
13