Mapa De Fuentes De Relés Y Bucles 9950 - GF Signet 9950 Instrucciones De Operación

Tabla de contenido

Publicidad

Mapa de fuentes de relés y bucles del 9950
Measurement
Frequency
Flow
pH
Terminal
ORP
Block 1
Cond. (2850)
Pressure
Level
Temperature
Salinity
DO
Measurement Modules
can be read by either
Channel 1 or Channel 2
Option
Conductivity
Module 1
Module
Socket
Option
Conductivity
Module 2
Module
Socket
Frequency
Flow
pH
ORP
Cond. (2850)
Pressure
Level
Temperature
Terminal
Salinity
Block 2
DO
Binary Input 1
Binary Input 2
Relay Module Socket
Binary Input 3
Binary input 4
Real-time
Time Interval
Clock
Calculation
Activation
Duration
Hold Measurement
While Active
68
Transmisor 9950
Map of 9950 Relay and Loop Sources
Input
Channel 1
CH1 Primary/Secondary
(Derived measurements are
available as a source when channels
are the same measurement type and
the derived measurements are
selected by the user)
Derived Measurement
Sources
(CH1 + CH2)
(CH1 – CH2)
(CH2 – CH1)
(CH1 : CH2)
(CH2 : CH1)
None
Sum
Difference
Ratio
% Passage
% Reject
% Recovery
A, B, C
CH2 Primary/Secondary
Channel 2
Binary Input (1-4)
Input
Hours, Min,
Sec, Days
Weekday
Relay Period Mode Timing Diagram
Period
Recovery
Activation
Time
Duration
Apéndice
Loop n Source
Loop and Relay
None
Input Sources
CH 1 Pri/Sec
CH 2 Pri/Sec
Function 1-4
Loop Source
Relay Source
Relay n Source
None
CH 1 Primary
CH 1 Secondary
CH 2 Primary
CH 2 Secondary
Function 1-4
Deriv. 1
Binary 1-4
Deriv. 2
Timer
Deriv. 3
Deriv. 4
Multiple
Source A
Mode A
Off / Low / High
Binary On / Binary Off
Parameters A
Set Low/High
Source B
Mode B
Off / Low / High
Binary On / Binary Off
Parameters B
Set Low/High
Date
Source C
Mode C
Off / Low / High
Binary On / Binary Off
Parameters C
Set Low/High
Multiple Relay Sources:
Channel1 (Pri or Sec), Channel2 (Pri or Sec) , and Binary
Inputs. (The same source can be used for A, B, and C)
Period
Recovery
Time
Hold Measurement
While Active
Loop and Relay Control Parameters
Loop n Mode
Linear
Log
Loop Mode
Relay Mode
Relay n Mode
Off
Low/High
Window In/Out
Cycle Low/High
PWM
Prop Pulse
USP
(Cond Only)
Error
Volume Pulse
Totalizer Pulse
Binary On
Binary Off
Period
Weekday
A | B | C
A & B & C
A | (B & C)
A & (B | C)
Loop n Param.
Label
4 mA Setpoint
20 mA Setpoint
Error Value
Adjust 4 mA
Adjust 20 mA
Loop
Parameters
Relay
Parameters
Relay n Param.
Label
Set Low
Set High
Hysteresis
Cycle Time
Pulse Min
Pulse Max
Max Rate
PWM Min
PWM Max
PWM Period
USP Percent
On Delay
Activate
Red Backlight
Set Volume
Pulse Width
Total Volume
Set Period Units
(Min, Hours, Days)
Set Period Interval)
First Start
Start Delay (Days)
Activation Days
Start Time
Duration Seconds
Recovery Seconds
Hold While Active

Publicidad

Tabla de contenido
loading