6
ADJUSTMENTS
6.6

SHIFT CONTROL CABLE ___________________________________________________

If traction drive system does not shift properly,
adjustment of the shift control cable may be required.
1. Disconnect clevis (N) from shift lever (P).
2. Place the shift control lever in the L position.
3. Rotate shift lever (P) clockwise until it locks into the
low speed detent.
4. Adjust cable nuts (M) as necessary until clevis (N)
aligns with mounting hole in lever (P).
5. If additional adjustment is required, cable may be
adjusted at the handle.
6. Test each position of shift control. Shift lever (P)
should lock into each detent at each stop of shift
control.
6.7

LIFT CABLE ______________________________________________________________

If aerator head does not raise or lower properly,
adjustment of the lift cable may be required.
1. Loosen both cable nuts (R). Lift valve should
automatically return to center.
2. Place lift control handle in center (Neutral) position.
3. Tighten nuts (R).
4. Test operation of lift control.
20
P
N
M
Figure 6F
R
Figure 6G