Fig. 05
6.2 - How to assemble the counterweight balancer (Install when the machine is
tilted only)
For operator safety always disconnect the air source before cleaning, lubricating
or performing any maintenance. The IM-4P was designed to be operated as a bench table
or tilting stand. The counterweight balancer spring is provided with the machine for
using just when the machine is tilted. Proceed as follow to attach the counterweight
balancer on the machine:
Fig. 07
6.3 - Oil level on lower edge of oil glad
INMES products are constructed to have long duration and are tested one by one.
However, we ship the machines without oil inside the lubricator glass and it is necessary
INMES INDUSTRIAL LTDA - GRAMPEADORA IM-4P – UNDERPINNER IM-4P
ENSAMBLADORA IM-4P
a) Tilt the working table by loosen the knobs on
the left and right sides of the stands.
b) Once the working table is tilted attach one end
of the spring over the bolt as shown in Fig. 07
and the other end of the spring attaches to
another bolt located besides the cylinder. Once
you have done this procedure then connect the
machine to the air source.
Fig. 06
34