Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SELECTION OF THE SETTINGS
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
DOWN
UP
(To enter the Special Menu keep pressed UP and DOWN at the same time for 5 seconds.
To exit the Special Menu pressed END or keep pressed UP and DOWN at the same time for 5 seconds)
MENU SP
Description
Re. s p
Space retrieve
Reversing on limit switch
R. Ot
Po. P r
Periodic Push Over
all. r
Antiintrusion alarm
Electrolock
T. s er
release time
Courtesy light management
L. t i
with timer
D ag
Events diagnostic
ph. t e
Auto-test photocells
Tolerance between stop and
Tl. o 1
obstacle motor 1 opening
Tolerance between stop and
Tl. 1
obstacle motor 1 closing
Tolerance between stop and
Tl. o 2
obstacle motor 2 opening
Tolerance between stop and
Tl. 2
obstacle motor 2 closing
Sensitivity on obstacle
s. o p1
Sensitivity on obstacle
S. l1
s. o p2
Sensitivity on obstacle
S. l2
Sensitivity on obstacle
Ps. r d
Enter password
END
Exit special menu
32
67410756
®
SPECIAL MENU FUNCTIONS TABLE USER 2 24V DG
SET
pk. e
0 15
D sb 3
D sb 8
D sb
O. Lo
O. O pe
Op. L
D sb 5
off
on
0 10
ph. i 2
ph. i
ph. 2
0 100
0 100
0 100
0 100
0 99
0 99
0 99
0 99
----
English
Description
Phototest economy
Output for Self-test ON only
during the operation of the motors.
Retrieves the inertia of the
motor after Stop or reversing
from 0% to 15 %
After reading the limit switch in closing
the motor inverts for the set time,
adjustable from 0 to 3sec.
Allows the repetition of the Pushover
function at a distance of time adjustable
from 0 to 8 hours at hourly intervals
If the limit switch is freed manually
it forces the reclosing of the gate
Only on closing limit switch
Only on opening limit switch
On limit switch in closing
and in opening
Sets the lock release
time from 0 to 5 s
When timer is ON the courtesy light
can be kept switched OFF
With timer ON courtesy light can
be kept ON
Shows last event
(See alarms table)
Auto-test active on Photo1 and Photo2
Auto-test active only on Photo1
Auto-test active only on Photo2
Adjusts the tolerance between stop
and obstacle
Adjusts the tolerance between
stop and obstacle
Adjusts the tolerance
between stop and obstacle
Adjusts the tolerance between
stop and obstacle
Adjusts the revesing sensitivity on
motor 1 in opening.
Note: Only with Encoder On active.
Adjusts the revesing sensitivity on
motor 1 in closing.
Note: Only with Encoder On active.
Adjusts the revesing sensitivity on
motor 2 in opening.
Note: Only with Encoder On active.
Adjusts the revesing sensitivity on
motor 2 in closing.
Note: Only with Encoder On active.
Allows the entering of a password
blocking the control unit parameters
modification (see page 38)
Select END and press OK to exit the special menu.
The special menu switches off automatically after 20 minutes.
REV 04 - 03/2013
USER 2 - 24V DG
Default
Set value
6
D sb
D sb
D sb
1
off
ph. 1 . 2
0
0
0
0
D sb
D sb
D sb
D sb