Tools for Cleaning Interfaces and Connectors
a) Optic fiber cleaner (for cleaning of optic connectors).
b) Optic fiber cleaning rod (for cleaning of optic outputs).
c) Optic fiber cleaning tissue (for cleaning optic interfaces).
d) Isopropyl alcohol.
e) Cotton ball.
f)
Paper tissue.
g) Cleaning brush.
h) Condensed air.
•
Preferred Procedure for Cleaning Interfaces and Connectors
As in figure 44. Preferred Procedure is as follows
a) Screw off the cap of flange.
b) Pinch the ceramics core between the thumb and the forefinger, rotate
meanwhile pull it out slowly.
c) Clean the laser head carefully.
d) Mount the ceramics core.
e) Screw on the cap of flange.
Page 50
Figure 44.- Structure of Flange.