SAFETY INFORMATION
IDROPELLBOX MUST NEVER BE MADE TO OPERATE
WITHOUT WATER IN THE SYSTEM.
MUST BE MADE WITH A PRESSURE OF ABOUT 1.5 BAR.
IT CAN BE DAMAGED IF IT IS IGNITED WITH NO WA-
TER IN THE SYSTEM.
• The boiler- replace is designed to heat water by means of
automatic combustion of pellets (wood with 6 mm diameter) in
the hearth.
• The only risks that may derive from using the boilerstove
pertain to non-compliance with the installation regulations,
direct contact with live electrical parts (internal), contact with
the re or hot parts, or foreign substances being put into the
boiler- replace.
• Should components fail, the boiler- replace is equipped with
safety devices to guarantee its automatic shutdown.
• These are activated without any intervention required.
• In order to function correctly, the boiler- replace must be
installed in accordance with the instructions given herein.
• Whilst functioning, the door must never be opened. In fact,
combustion is fully automatic and requires no manual interven-
tion.
• Under no circumstances should any foreign substances be put
into the hearth or the hopper.
• Do not use ammable products to clean the smoke channel
(the ue section connecting the boiler- replace smoke outlet to
the chimney ue).
• Hearth and hopper components must only be cleaned with a
vacuum cleaner.
• The glass can be cleaned when COLD with a suitable product
(e.g. GlassKamin) and a cloth. Do not clean when hot.
In accordance with Art. 13 of the Legislative Decree No. 151, dated 25 July 2005, "Implementation of Directives: 2002/95/EC,
2002/96/EC and 2003/108/EC, pertaining to the reduction of hazardous substances used in electrical and electronic equipment,
as well as disposal of waste". The crossed-out wheeled bin symbol shown on the equipment or on the packaging indicates that
the product must be disposed of separately at the end of its useful life. Therefore, at the end of the equipment's useful life, the
user must hand in the equipment to suitable collection facilities for electrical and electronic waste, or return it to the retailer
when a new, equivalent appliance is purchased in a ratio of one to one.
• Ensure that the boiler- replaces are installed and ignited by a
quali ed Edilkamin DEALER, in accordance with the
instructions given herein.
• When the boiler- replace is in operation, the exhaust pipes and
door become very hot (do not touch without wearing the thermal
glove).
• Do not place anything, which is not heat resistant near the
boiler- replace.
• NEVER use liquid fuel to ignite the boiler- replace or rekindle
the embers.
• Do not obstruct the ventilation apertures in the room
where the boiler- replace is installed, nor the air inlets of the
boiler- replace itself.
• Do not wet the boiler- replace and do not go near electrical
parts with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The boiler- replace must be installed in a room that is suitable
for re prevention and equipped with all that is required (power
and air supply and outlets) for the boiler- replace to function
correctly and safely.
• The boiler- replace must be kept in a room where the tempera-
ture is above 0 °C.
• Use appropriate anti-freeze additives for the water of the
system.
• Ensure that the temperature of the return water is at least 45-50 °C.
ATTENTION:
• SHOULD IGNITION FAIL, DO NOT RE-IGNITE UNTIL
YOU HAVE EMPTIED THE COMBUSTION CHAMBER.
• THE PELLET EMPTIED FROM THE COMBUSTION
CHAMBER MUST NOT BE DEPOSITED INSIDE THE
HOPPER.
INFORMATION FOR USERS