Gas Heater Hook-Up - CalSpas Fitness 2400 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Gas Heater Hook-up

Ultimate Fitness Series spa owners may buy and install a separate gas heater and pump for use with their spa. This
option may be purchased separately from your local distributor.
Spa owners are responsible for ensuring installation of their gas heater conforms to local, state, and federal
regulations. The electrical and gas installation must be performed by contractors and approved by a local building /
electrical inspector. Failure to do so may void your warranty.
All Ultimate Fitness Series spas are plumbed with a gas heater ready union located inside the cabinet at either the
front or rear, depending on the model. (See the figures below and on the next page.) Properly installed, they can be
attached to an external gas heater. Customers are responsible for creating openings in the panel to accommodate
the lines and wiring. The gas heater should be located not less than 3m and no more than 7.6m away from the
spa.
To connect the plumbing for an external gas heater:
1.
Disconnect the ready union.
2.
Cut off both sides of the union and discard it.
3.
Create two 6.35 cm diameter holes through the spa panel.
4.
Use two 5 cm (2") couplings to connect the hoses to 3m - 4.5m 5 cm (2-3/8") diameter PVC lines.
5.
Connect PVC lines to the gas heater.
2009 Portable Spa Owner's Manual