ELGA-TB-G/-KF/-RF
Interfaces for mounting components
on the cover
e.g. with foot mounting HPE
1) è www.festo.com/catalogue
Fig. 8
Note
Danger of screws being pulled out if the axis is only mounted to the covers and the
torque load around the longitudinal axis is too great.
If there are heavy loads, mount the axis to the profile with additional mounting
components.
Select mounting components or accessories (è www.festo.com/catalogue).
Mount the mounting components outside the positioning range (avoid collisions).
Fasten axis.
Evenly tighten screws.
Size
Screw (cover)
Tightening torque
Tab. 1
5.1.2
Mount attachment components
Requirements
Note
A warped attachment component bends the slide
and shortens the service life of the guide.
Use an attachment component with a flat surface.
Flatness:
– ELGA-TB-G: t = 0.03 mm
– ELGA-TB-KF: t = 0.01 mm
– ELGA-TB-RF: t = 0.01 mm.
34
on the profile
1)
e.g. with slot nuts NST
70
M5
[Nm]
5.9
1)
e.g. with profile mounting MUE
80
120/150
M5
M6
5.9
9.9
Fig. 9
Festo – ELGA-TB-G/-KF/-RF – 1502c English
1)
M8
24