InsTAllATIon InsTRUCTIons:
Carefully review all of these instructions BEFORE proceeding to install and operate your air conditioner unit .
Failure to do so may cause damage, injury, or bodily harm including permanent disability and/or death .
loCATIon:
• The air conditioner should be placed on a firm foundation to minimize noise and virbration . For safe and
secure positioning, place the unit on a smooth, level floor strong enough to support the unit .
• The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces . Use caution
when rolling on carpet surfaces . Do not attempt to roll the unit over objects .
• The unit must be placed within reach of a properly rated grounded socket .
• Never place any obstacles around the air inlet or outlet of the unit .
• Allow 1 to 3 feet (30cm to 100cm) of space from the wall with for efficient air-conditioning and prevent
overheating .
exHAUsT Hose InsTAllATIon:
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode .
InsTAlleD—Cooling, heat pump, or auto mode
ReMoveD—Heating (electric), fan or dehumidify mode
1 . Install the adapter A or adapter B onto the exhaust hose as shown in
Figure A or Figure B .
2 . Resert the hook of the Exhaust hose into the hole seat of the air
outlet and slide down the Exhaust hose along the arrow direction
for installation . (see Figure C)
The exhaust hose can be installed into the wall (not applicable to units
without adaptor A, expansion plugs and wood screw accessories) .
1 . Prepare a hole in the wall . Install the wall exhaust adaptor A onto the
exterior/outdoor wall using the 4 expansion plugs and wooden screws .
Be sure to fasten securely . (see Figure D)
2 . Attach the Exhaust hose to wall Exhaust adaptor A .
noTe: Cover the exhaust hole using the adaptor cap when not in use .
The exhaust hose can becompressed or extended moderately according to
installation requirements, but it is preferable to shorten the hose to desired
length .
IMPoRTAnT: DO NOT OVERBEND OR KINK THE EXHAUST HOSE (see Figure E)
CAUTIon exHAUsT PoRT
Make sure that there are no obstacles within 18" or 50cm around the exhaust
outlet in order for the exhaust system to work properly .
5