InsTAllATIon InsTRUCTIons (ConTInUeD):

WATeR DRAInAGe:

Certain functions of your air conditioning unit create condensation and must evacuate accumulated water .
Please carefully follow these instructions according to your operating and usage conditions .
DeHUMIDIFyInG MoDe: Remove the upper drain plug from the back of the
unit, install the drain connector (5/8 universal female mender) with 3/4" hose
(available in local hardware stores) . For the models without a drain connector,
simply attach the drain hose to the hole . Place the open end of the hose adap-
tor directly over the drain area in your basement floor . (see Figure F)
HeAT PUMP MoDe: Remove the lower drain plug from the back of the unit,
install the drain connector (5/8" universal female mender) with standard
3/4" hose (available in local hardware stores) . For the models without drain
connector, just attach the drain hose to the hole . Place the open end of the
hose adaptor directly over the drain area in your basement floor . (see Figure
G) .
noTe: Make sure the hose is secure so there are no leaks . Direct the hose to-
ward the drain, making sure that there are no kinks that will stop water flow .
Place the end of the hose into the drain and make sure the end of the hose is
down to let the water flow smoothly . (see Figures F, G, & H) . Do not lift up the
hose to cause drainage to fall back in . (see Figure I) .
When the water level of the bottom tray reaches a predetermined level, the unit
beeps 8 times, the digital display area shows error P1 . At this time the air condition-
ing/dehumidification process will immediately stop . However, the fan motor will
continue to operate (this is normal) .
Carefully move the unit to a drain location, remove the bottom drain plug and let the
water drain away (see Figure J) . Reinstall the bottom drain plug and restart the ma-
chine until the P1 symbol disappears . If the error repeats, call for service .
noTe: Be sure to reinstall the bottom drain plug before using the unit .
$$$ sAve & ConseRve eneRGy
• Use the unit in the recommended room size .
• Locate the unit where furniture cannot obstruct the air flow .
• Keep blinds/curtains closed during the sunniest part of the day .
• Keep the filters clean .
• Keep doors and windows closed to keep cool air in and warm air out