SYMPTOM
Engine will not start.
No discharge at nozzle when
trigger mechanism is squeezed.
Low or fluctuating pressure.
Water is leaking from Heat DumpValve. Water temperature is too high.
Oil appears milky or foamy.
Oil leaking from unit.
Detergent will not siphon into
Low Pressure Detergent mode.
Water flows back into detergent
container.
Water flows from the nozzle when the
trigger gun is locked in the "OFF"
position.
20

TROUBLESHOOTING

PROBABLE CAUSE
Various engine problems.
Unit components are frozen.
Inadequate water supply.
Kink in water inlet hose.
Kink in high pressure discharge hose.
Water inlet screen obstructed.
Pump sucking air. (Prime eliminated)
Adjustable Grip on Dual Lance
is not in high pressure mode.
Obstructed or worn spray nozzle.
Damaged or obstructed valve assy.
on pump.
Pump packings worn.
Unloader/Bypass valve not operating
correctly.
Defective valve.
Water in oil.
Worn seals or o-rings.
Detergent strainer is not completely
submerged in detergent solution.
Detergent strainer obstructed.
Detergent hose cut, obstructed or
kinked.
Detergent adjusting knob turned to
closed position.
Adjustable grip on dual lance is
not in low pressure mode.
Nozzle assembly is plugged.
Too many high pressure hose
extensions attached to the water outlet.
Ball & Spring in Venturi stuck.
Ball & Spring in Venturi reversed,
missing or corroded.
Trigger gun is malfunctioning.
REMEDY
Refer to the Engine Manual
accompanying your unit.
Allow to thaw. If any part of the unit
becomes frozen; excessive
pressure may build up in the unit
which could cause the unit to burst
resulting in possible serious injury to
the operator or bystanders.
Ensure hose is 3/4" diameter and
incoming water supply is turned on.
Remove kink.
Replace kinked high pressure hose.
Remove screen, clean or replace.
Tighten all water intake connections
Eliminate leaks in intake line.
Turn grip counterclockwise to
to high pressure.
Remove, clean or replace.
Remove, inspect, clean or replace.
Replace packings.
Repair or replace.
Do not allow unit to operate in
bypass mode (with the trigger gun
closed) for more than three minutes.
Replace.
Change pump oil. Fill to proper
level.
Contact Service.
Check, submerge if necessary.
Inspect, clean or replace.
Inspect, clean or replace.
Open adjusting knob. Refer to
"Cleaning with Detergents" pg. 17.
Turn grip clockwise to move to low
pressure.
Clean or replace.
Use one extension maximum.
Remove, clean or replace.
Remove, clean or replace.
Repair or replace.