I
nstalling the FA-805 power supply.
3,5 x 50
DIN-7971
The power supply can be installed on a DIN 46277 guide
by simply pressing it. To disassemble the power supply,
use a plain screwdriver to lever it, as it is shown on
on the picture.
The power supply needs 7 elements over the DIN
guide.
Place the protection cover once the input terminals are wired.
L
ock release installation.
If the lock release is installed in a metal door, use a
drill
and tap the hole.
In case of wood door, use a
IMPORTANT: the lock release must be of 12V a.c. or d.c (see pages 67 to 70).

POWER SUPPLY INSTALLATION

The power supply must be installed in a dry and
3,5 x 50
protected place. Remember the current regu-
DIN-7971
lation forces you to protect the power supply
with a magnetocaloric switch.
To install the power supply on the wall, drill two holes of
Ø
6mm and insert the wall plugs. Hold the power supply
by means of the specified screws.

LOCK RELEASE INSTALLATION

Ø 3
mm drill.
DIN 46277
3,5 x 25
DIN-7972
Ø3,5mm
M 4 x 8
DIN-963