To avoid overheating of the electric motor, this compressor is designed for intermittent operation as indicated on the
technical dataplate (for example, S3-25 means 2.5 minutes ON, 7.5 minutes OFF).
© Stanley Bostitch
SAVE THESE INSTRUCTIONS AND MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL!
GB Not to be reproduced without permission. Unauthorised copies of this document do not constitute CE
compliance for the products.
OPERATION AND MAINTENANCE
NOTE: The information contained in this Instruction Manual is designed to assist you in the safe operation and
FR Reproduction interdite sans permission préalable. Les copies non autorisées de ce document ne signifient en
maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that
rien que les produits soient conformes aux normes CE.
differ from those on your own compressor.
INSTALLATION
DE Vervielfältigung nicht ohne Genehmigung gestattet. Unzulässig erstellte Kopien dieses Dokuments erfüllen nicht
Remove the compressor from its packing, makes sure it is in perfect condition, checking if it was damaged during
die CE-Richtlinien für Produkte.
transport, and carry out the following operations:
NL Mag niet worden vermenigvuldigd zonder toestemming. Onrechtmatige kopieën van dit document willen niet
Fit the wheels and rubber tab on the tanks on which they are not already fitted, observing the instructions in (fig.1a &
zeggen dat de producten voldoen aan de CE-vereisten.
1b). Also fit the Air Filter (Fig 2). Position the compressor on a flat surface or with a maximum permissible inclination of
10°, in a well aired place, protected against atmospheric agents and not in a place subject to explosion hazard. If the
surface is inclined and smooth, check if the compressor moves while in operation - if it does, secure the wheels with
DK Må ikke gengives uden tilladelse. Uautoriserede kopier af dette dokument udgør ikke CE overholdelse for
two wedges. If the surface is a bracket or a shelf top, make sure it cannot fall, securing it in a suitable way. To ensure
produkterne.
good ventilation and efficient cooling, the compressor must be at least 100 cm from any wall. Compressors fitted on
the tank, with fixed feet, should not be rigidly secured to the ground. In this case, we advise you to fit 4 anti-vibration
supports. Verify that the tanks have been drained and are clear of any moisture or dirt.
FI Ei saa jäljentää ilman lupaa. Tämän asiakirjan ilman valtuutusta tehdyt kopiot eivät muodosta tuotteille CE-
yhdenmukaisuutta.
INSTRUCTIONS FOR USE
GR Απαγορεύεται η αναπαραγωγή χωρίς προηγούμενη άδεια. Τα μη εξουσιοδοτημένα αντίγραφα του παρόντος
-Take care to transport the compressor correctly, do not overturn it or lift it with hooks or ropes. Check oil level,
consulting the reference marks on the stick (fig. 3).
εγγράφου δεν αποτελούν συμμόρφωση CE για τα προϊόντα.
Oil lubricated compressors may come with a bottle of oil to fill or top up the compressors - note that not all oil supplied
IT Vietata la riproduzione senza permesso. Le copie non autorizzate di questo documento non garantiscono la
may be needed to fill the unit to the correct level.
conformità CE per i relativi prodotti.
NOTE: Some units (MRC6, RC-10) are equipped with an oil-free pump. There is no oil to replace or check.
NO Skal ikke reproduseres uten tillatelse. Ikke godkjente kopier av dette dokumentet oppfyller ikke kravene for CE-
ELECTRICAL CONNECTION
merking for produktet.
Single-phase compressors are supplied with an electrical cable and a two-pole & earth plug. The compressor must be
connected to a grounded power socket (fig.4).
PT Reprodução proibida sem autorização prévia. As cópias não autorizadas deste documento não estão em
conformidade com a CE para os produtos.
IMPORTANT: Never use the ground socket instead of the neutral wire. The ground connection must be made to meet
safety standards (EN 60204). The plug of the power cable must not be used as a switch, but must be fitted in a power
socket controlled by a suitable differential switch (thermalbreaker).
ES Prohibida la reproducción sin permiso. Las copias no autorizadas de este documento no suponen la
conformidad con las normas CE de los productos.
STARTING
Check that the mains power matches that indicated on the electrical data-plate (fig.5) - the permissible tolerance range
is +/-5%. Turn or press into position "0" (according to the type of pressure switch fitted on the appliance) the knob
SE Prohibida la reproducción sin permiso. Las copias no autorizadas de este documento no suponen la
located on the upper section (fig. 6A, 6B, 6C). Fit the plug in the power socket and start the compressor, turning the
conformidad con las normas CE de los productos.
pressure switch knob into position "I".
PL Niniejszy dokument nie może być kopiowany bez pozwolenia. Nieautoryzowane kopie niniejszego dokumentu nie
The compressor is fully automatic, and is controlled by the pressure switch which stops it when tank pressure
stanowią deklaracji zgodności CE prezentowanych produktów.
reaches maximum value and restarts it when it falls to minimum value. The pressure difference between maximum and
minimum values is usually about 2 bar (29 psi). E.g.: the compressor stops when it reaches 8 bar (116 psi - maximum
operating pressure) and restarts automatically when the pressure inside the tank drops to 6 bar (87 psi). After
CZ Niniejszy dokument nie może być kopiowany bez pozwolenia. Nieautoryzowane kopie niniejszego dokumentu nie
connecting the compressor to the power line, load it to maximum pressure and check exactly how the machine is
stanowią deklaracji zgodności CE prezentowanych produktów.
operating.
SK Rozmnožovanie bez povolenia je zakázané. Neoprávnené kópie tohto dokumentu nie sú v súlade s CE pre dané
NOTE: The head/cylinder/delivery tube unit can reach high temperatures. Take care when working near these parts,
and do not touch them to avoid possible burns.
výrobky.
IMPORTANT
HU A dokumentum engedély nélkül nem sokszorosítható. Az engedély nélkül sokszorosított dokumentum nem jelenti
The electro-compressors must be connected to a power socket protected by a suitable differential switch
a termék CE-megfelelőségét.
(thermal-breaker). The motor is equipped with an automatic thermal breaker located inside the winding - this stops
the compressor when motor temperature reaches excessively high values (180
compressors restart automatically after 10 to 15 minutes.
RO Reproducerea neautorizată este interzisă. Copiile neautorizate ale acestui document nu reprezintă
conformitatea CE pentru produse.
C). If the breaker is tripped, the
o