Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DC Inverter U-match Series Cassette Type Unit
Notice: Check the above items and adopt the corresponding
corrective measures. If the air conditioner continues to function poorly, please
stop the air conditioner immediately and contact Gree's authorized local service
center. Ask our professional service staff to check and repair the unit.

5.2 Error Code

①.
If abnormal things (for example, awful smell) occur, please stop the unit
immediately and disconnect power. Then contact Gree's authorized service
center. If the unit continues to run in abnormal situations, it may get damaged
and cause electric shock or fire hazard.
②.
Do not repair the air conditioner by yourself. Improper maintenance will cause
electric shock or fire hazard. Please contact Gree's authorized service center
and send for professional service staff to repair.
If the display panel or wired control displays an error code, please refer to the
error code meaning stated in the following table.
Error
Number
code
1
E1
2
E2
3
E3
4
E4
5
E6
6
E8
7
E9
8
F0
9
F1
10
F2
11
F3
12
F4
13
F5
14
C5
15
EE
16
PF
Error
Compressor high pressure protection
Indoor anti-freeze protection
Compressor low pressure protection, refrigerant lack protection
and refrigerant colleting mode
Compressor air discharge high-temperature protection
Communication error
Indoor fan error
Water-full protection
Indoor ambient temperature sensor error
Evaporator temperature sensor error
Condenser temperature sensor error
Outdoor ambient temperature sensor error
Discharge temperature sensor error
Wired control temperature sensor error
IDU jumper cap error
IDU or ODU memory chip error
Electric box sensor error
Warning