36 | TTM 2104/2204 | Network
6.
Network
To display a list of the faults that occurred and the system history in the address bar of the browser, enter
"IP Address Master"/special/permanent.log
New events are at the bottom of the list. The time appears in the list in UTC format. If there is a network problem
between the master and satellite, this is saved there in the following manner:
2016-08-05T18:26:54.473701Z;2;
error-code: 0x0400030BBB,
id:
3003,
category: Permanent (4),
action: User action - see handbook
EXCLUSIVE, Network connection between satellite and master not working.
i
Additional errors that are not saved in the permanent.log file are listed in the following table.
Description / message
Possible cause
R Voltage supply for satellite defective / not
No network connection
between master and
satellite, see Fig. 7.
R Network connection between master and satellite
R Module in satellite incorrectly configured.
R Satellite defective.
R Voltage supply for master defective / not
No network connection
between master and
Smart TV (no entry in
R Master not activated.
R Network connection between master and Smart
permanent.log file), see
Fig. 8.
R Master module defective.
R Incorrect network configuration
No connection to
module, even though
it flashed on startup
and faulty physical
connection can be ruled
out
Fig. 7:
Failure indication on PC monitor
|
1 691 206 007
2017-06-19
. A list of all important events since manufacturing of the module appears.
(3),
connected.
interrupted / defective.
connected.
TV interrupted / defective.
Remedy / action
R Check voltage supplied to satellite.
R Check network connection between master and
satellite and, if necessary, replace network cable
/ switch.
R Check network configuration and correct.
R Replace module.
R Check voltage supply to master.
R Switch on master.
R Check network connection between master and
Smart TV and, if necessary, replace network
cable / switch.
R Replace module.
R Create IP configuration for TSS PC/laptop
R Check client configuration and make settings
required for customer situation
Fig. 8:
Failure indication on Smart TV, no connection
between master and Smart TV
Robert Bosch GmbH

Publicidad

loading

Este manual también es adecuado para:

Ttm 2204