8.3 Simple controller function

When this function is active, the controller cannot manage a step cycle but it
regulates according to a single setpoint (programmed temperature) which is
selectable by the user.
Press stop and follow the points below:
Press
Red display visualizes the selected
1
CYCLE
cycle.
Red display visualizes spu while
2
START
STOP
green display shows the setpoint.
Increases or decreases the
3
setpoint value.
The controller modulates the
4
command output to keep the
START
STOP
programmed temperature.
Visualizes ciclically the controller
5
STEP
values.
9

Programmer functions

9.1 Hold function

This function allows to interrupt a cycle: red display visualizes hoLd and cycle is
stopped. It is possible to modify setpoint pressing
To start this function proceed as follows:
• Enter configuration and select en. on parameter 17 HLd.f .
• With cycle in progress press

9.2 Automatic Tuning

This procedure allows the user to have a precise regulation also without knowledge
of PID regulation. Selecting auto on parameter 06 tune , controller check process
oscillations and modifies PID parameters if the difference between process and
setpoint values is greater than value on parameter 53 m.G.tu.
Parameters 53 m.G.tu. , 54 mn.p.b. , 55 ma.p.b. and 56 mn.i.t. can be modified
entering the password 5678.
2
Access to this function may be enabled on parameter 16
Display
for 1": function will be started or stopped.
CYCLE
2
Increase until visualize tHer .
Enter the chosen setpoint.
To modify the setpoint spu press
and the arrow keys.
STEP
To exit this function, press
for 1".
or
.
sp.fu
Do
START
STOP
.
User manual - ATR902 - 15