8

Command Hysteresis

c. HY.
Hysteresis in ON/OFF or dead band in P.I.D. for command output.
-99.9...+99.9 tenths of degree.> Default: 1.0.
9

Proportional Band

P.b.
Process inertia in degrees.
0.0 ON/OFF if also t.i. equal to 0. > Default.
0.1...999.9 tenths of degree.
10

Integral Time

t. i .
Process inertia in seconds.
0.0...999.9 seconds. Integral 0 disabled. > Default: 0.0.
11

Derivative Time

t.d.
Normally ¼ of integral time.
0.0...999.9 seconds. Derivative 0 disabled. > Default: 0.0.
12
Cycle Time
t.c.
Cycle time (for P.I.D. on contactor 10"/15", for P.I.D. on SSR 1")
1...300 seconds. > Default: 10.
13
Command State Error
c. s.e.
SContact status for command output in case of error.
Open Contact > Default
o.c.
Closed Contact
c.c.
14
Visualization Display 2
ui.d.2
Set visualization on display 2 during a cycle
e.st.s. (End Step Setpoint) End temperature of operating step
(Real Setpoint) Updated according to the selected gradient
r.spu
(Cycle Number) Number of operating cycle. > Default
cy.nu.
(Step Number) Number of operating step
st.nu.
Time elaplsed from cycle start
time
15
Delayed Start
de.st.
Enables initial waiting for delayed start of cycle
(Disabled) Initial waiting disabled. > Default
dis.
(Enabled) Initial waiting selectable by the user.
en.
User manual - ATR902 - 21