Specifications (cont.)
Pressures
Minimum Flow Rate
Temperatures
Programmable Temperature
Default Temperature at Start-up
Minimum Mixed Temperature Differential
from Hot Supply
Temperature Stability at Recommended
Supply Conditions
Ambient Temperature
Maximum Relative Humidity
Electrical
Electrical Rating
Data Cable Length
*In commercial applications where there is a large difference in hot and cold supply pressures or frequent
fluctuation in either supply line is anticipated, it is strongly recommended that pressure regulators be
installed.
Tools and Materials
Before You Begin
NOTICE: Do not install the valve under a whirlpool surround or any location where the temperature may
exceed 104°F (40°C). The valve and its integrated power supply is rated to operate in temperatures up to
104°F (40°C).
NOTICE: Do not apply excessive heat near the valve or apply flux or acids directly onto the valve. This
valve contains plastic and rubber components which will melt if heat is directly applied.
NOTICE: Do not apply petroleum-based lubricants to the valve components. Doing so will damage the
valve components.
NOTICE: Do not use oil-based, non-setting compounds, such as plumbers putty, on the threaded
connections.
Kohler Co.
1.6 gal/min (Less than 72 psi dynamic pressure.)
6 l/min (Less than 500 kPa maintaining pressure.)
2.1 gal/min (Greater than 72 psi dynamic pressure.)
8 l/min (Greater than 500 kPa maintaining pressure.)
Max 120°F (49°C) Min 86°F (30°C) Full cold may also be selected.
100°F (38°C)
3.6°F (2°C)
+/- 1.6°F (1°C)
Greater than 34°F (1°C), Max 104°F (40°C)
95% non-condensing
120 V, 15 A, 60 Hz
25' (7.6 m)
Plus:
• (2) 1/2" Union Connectors
• Wood and Framing Materials
• PEX Tubing, Copper Tubing, or PVC
• (2) Water Hammer Arrestors (Recommended)
• (2) Supply Shut-Off Valves
Hacksaw or Tube Cutter
3
Sealant
Solder
Tape
1240338-2-A
Propane
Torch