Descargar Imprimir esta página

Important - Sime OPEN.zip 25 BF TS Instrucciones Para El Instalador

Ocultar thumbs Ver también para OPEN.zip 25 BF TS:

Publicidad

Idiomas disponibles

Idiomas disponibles

INDEX
1
DESCRIPTION OF THE APPLIANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 53
2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 56
3
CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 62
4
USE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 64
FONDERIE SIME S.p.A, Via Garbo 27 - Legnago (VR) - Italy, declares that its hot water boilers bearing the CE mark pursuant to Gas
Directive 90/396/CEE and equipped with safety thermostat with maximum temperature set at 110°C, are not included in the field
of application of European Pressure Directive (PED) 97/23/EEC since they comply with the requisites specified in article 1, clause
3.6, of the same.
The first time the boiler is switched on, the following checks should be made:
– Check that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
– Make sure that the electrical connection is correct and that the earth wire is connected to a good earth plant.
– Open the gas tap and check the seal of the couplings including that of the burner.
– Make sure that the boiler is suitably adapted for functioning with the type of gas supplied.
– Check that the combustion products evacuation duct is free and/or correctly fitted.
– Make sure that any shutters are open.
– Make sure that the plant has been loaded with water and that the air has been fully bled off.
– Check that the circulator is not blocked.
– Bleed any remaining air from the gas tube using the special tapping vent placed at the gas valve entry.
– The installer must teach the user how the boiler functions and explain the safety devices, and must also hand over to
him/her the logbook.
INSTALLER'S INSTRUCTIONS

IMPORTANT

51

Publicidad

loading

Este manual también es adecuado para:

Open.zip 30 bf ts