Safety Manual
16 user interface
16.1 Scrolling help texts in display line 3
[01]
Set correct password
[02]
enter advanced setup menu?
Select temperature input
[03]
Select current input
[04]
Select 0-20 ma input range
Select 4-20 ma input range
[05]
Select TC sensor type
Select Ni sensor type
Select pt sensor type
[06]
Select pt10 sensor type
Select pt20 sensor type
Select pt50 sensor type
Select pt100 sensor type
Select pt200 sensor type
Select pt250 sensor type
Select pt300 sensor type
Select pt400 sensor type
Select pt500 sensor type
Select pt1000 sensor type
[07]
Select Ni50 sensor type
Select Ni100 sensor type
Select Ni120 sensor type
Select Ni1000 sensor type
[08]
Select TC-B sensor type
Select TC-e sensor type
Select TC-J sensor type
Select TC-K sensor type
Select TC-L sensor type
Select TC-N sensor type
Select TC-R sensor type
Select TC-S sensor type
Select TC-T sensor type
Select TC-u sensor type
Select TC-W3 sensor type
Select TC-W5 sensor type
Select TC-Lr sensor type
[09]
Select 2-wire sensor connection
Select 3-wire sensor connection
Select 4-wire sensor connection
[11]
Select Celsius as temperature unit
Select Fahrenheit as temperature unit
[12]
Select 0-20 ma output range
Select 4-20 ma output range
Select 20-0 ma output range
Select 20-4 ma output range
[13]
Select no error action - output undefined at error
Select downscale at error
Select NaMuR Ne43 downscale at error
Select NaMuR Ne43 upscale at error
[14]
Set temperature for analogue output low
[15]
Set temperature for analogue output high
[16]
enable Rail status signal output?
18
9113 TeMpeRaTuRe / ma CONVeRTeR
Version No. V5R0
enter SIL setup
[17]
enter simulation mode
enter RaIL setup
perform process calibration
enter language setup
enter password setup
enter display setup
perform memory operations
Load saved configuration into 9113
[18]
Save 9113 configuration in 4501
adjust LCD contrast
[19]
adjust LCD backlight
[20]
[21]
Write a 5-character channel TaG
[22]
Show analogue input value in display
Show analogue output value in display
Show TaG in display
alternate shown information in display
enable password protection?
[23]
Set new password
[24]
Select language
[25]
Select channel to calibrate
[26]
[27]
Calibrate input low to process value?
[28]
Set value for low calibration point
[29]
Calibrate input high to process value?
[30]
Set value for high calibration point
[31]
use process calibration values?
[32]
Select channel to simulate
[33]
Set the input simulation value
[34]
enable SIL configuration lock?
0-20 ma is not a valid output range for SIL
operation
[35]
Set analog output response time in seconds
[36]
Select internal temperature sensor
Select CJC connector (accessory)
[37]
...is channel using process-compensated
calibration data?
[38]
Configuration SIL status (Open / Locked)
[40]
Sensor wire breakage
[41]
Sensor short circuit
[42]
Input underrange
[43]
Input overrange
[44]
Input error - check input connections and
reset power
[45]
Output error - check connections and reset
power
[46]
Flash memory error - check configuration
[47]
Invalid configuration type or version
[48]
Hardware error
[49]
CJC sensor error - check device temperature
[50]
CJC error - check CJC connector block
[51]
No communication