Installation and Maintenance Instructions
3/4" NPT PIPE

Surface-Mounting the Beacon (151XST-S)

To surface mount the beacon:
1.
See Figure 2. Use the mounting base as a template to mark the
location of the two mounting holes.
2.
Drill a 9/32-inch (7.143 mm) hole at each mark.
3.
Secure the beacon to the mounting surface with installer
supplied hardware.
10

Figure 1 Pipe-mounted beacon

Models 151XST and 151XST-S
151XST LIGHT
ASSEMBLY
SET SCREW
290A6904