Cable Ties
Air Line
Hydraulic
Hose
Fig. 19
Attach black wire
to one motor wire.
White
Black
Green
208-230V 60Hz
Single Phase
Attach ground wire here.
Attach ground wire to
screws provided.
Fig. 20
Column
Fill/Breather Cap
Power Unit
Attach white
wire to one
motor wire.
NOTES:
1. Unit not suitable for use in unusual conditions. Contact Rotary for
2. Control Box must be field mounted to power unit.
3. Motor rotation is counter clockwise from top of motor.
10
IMPORTANT
Use separate circuit for each power unit.
Protect each circuit with time delay fuse or circuit breaker. For
single phase 208-230V, use 20 amp fuse. Three phase 208-240V,
use 15 amp fuse. For three phase 400V and above, use 10 amp
fuse. For 3Ø wiring see Fig. 21. All wiring must comply with NEC
and all local electrical codes.
Note: 60Hz. single phase motor CAN NOT be run on 50Hz. line
without a physical change in the motor.
12. Hydraulic Fluid Filling: System capacity is fourteen (14)
quarts. Use Dexron III ATF. Remove fill/breather, Fig. 19. Pour in
thirteen (13) quarts of fluid. Replace fill/breather. Start motor and
raise lift to full rise. Lower onto latches.
Note: If fill/breather, Fig. 19, is lost or broken, order replacement.
Single Phase Power Unit
MOTOR OPERATING DATA TABLE - SINGLE PHASE
LINE VOLTAGE
208-230V 50Hz.
208-230V 60Hz.
Note: 60Hz. Single phase motor CAN NOT be run on 50Hz. line
without a physical change in the motor.
Black
230V 60Hz
Green
Single Ph
White
MOTOR OPERATING DATA TABLE - THREE PHASE
LINE VOLTAGE
RUNNING MOTOR VOLTAGE RANGE
208-240V 50/60Hz.
400V 50Hz.
440-480V 50/60Hz.
575V 60Hz.
moisture and dust environment duty unit.
RUNNING MOTOR VOLTAGE RANGE
197-253V
197-253V
Up
Switch
Black
Black
M
White
197-253V
360-440V
396V-528V
518V-632V