L1
L2
3 Phase
L3
Supply
PE
Fig. 21
Three Phase Power Unit
MOTOR OPERATING DATA TABLE - THREE PHASE
LINE VOLTAGE
RUNNING MOTOR VOLTAGE RANGE
208-240V 50/60Hz.
400V 50Hz.
440-480V 50/60Hz.
575V 60Hz.
(4) M5 x 45 PHMS, Plated
1
2
3
4
MOTOR
5
6
DRUM
SWITCH
L3
L2
197-253V
360-440V
396V-528V
L1
518V-632V
Gasket
Drum Switch
And Cover
(4) M5 x 10 PHMS, Plated
Capacitor Box To Power Unit
Capacitor Box Attachment
L3
T3
T9
T6
L2
T2
T8
T5
L1
T7
T4
T1
440-480V 50/60 Hz. 3Ø
208-240V
50/60Hz. 3Ø
11
Re-seal Between
Box And Spacer
Capacitor
With Silicone
Box
Sealer
T3
T9
T6
T2
T8
T5
T7
T4
T1
380-400V 50 Hz. 3Ø
T3
V2
W1
T2
V1
U2
T1
U1
W2
575V 60 Hz. 3Ø