Problem
Heating time elapses,
but radiator does not
heat
Heating time elapsed,
blank is not plasticized
sufficiently
Scanner not active
Unit does not reach the
pre-adjusted pressure
Unit makes fizzy sounds
during thermoforming
Cause
Quartz radiator defect
Temperature monitor
was activated
Lifetime of quartz
radiator exceeded
Heating time was
too short
Wrong heating time
was chosen
Scanner in sleeping
position
Scanner or electronics
defect
Line pressure too low
Ventilation valve
not closed
Tension ring has been
placed wrongly into
plate reception
Connection hose
leaky between valve
and cylinder
Aid
Exchange quartz
radiator
Exchange temperature
monitor
Exchange quartz
radiator
Prolong heating time
by 5–10 sec.
Scan correct barcode
Press OK key briefly
Electronics have to be
checked by an expert or
exchanged, if necessary
Increase line pressure
Close ventilation valve
Put tension ring into
correct position
Unit has to be
controlled by an expert,
connection hose
has to be exchanged,
if necessary