5. OPERATION
INITIAL START-UP
Warm-up time of 15 minutes stabilizes the measured values after switching on.
5.1 SWITCHING ON/OFF
•
Switch on the scale by pressing
•
After self checking, display will be come to normal weighing mode.
•
To switched off the scale, press
5.2 ZEROING
Environmental conditions can lead to the balance exactly zero in spite of the platform not taking any strain. However, you can set the
display of your balance to zero any time by pressing
5.3 USING TARE
The weight of any container can be tared by pressing
weighed is always displayed.
TARING A CONTAINER
•
Load weight on the hook.
•
Press
key. Zero is displayed, and tare is subtracted. And
•
Remove weight from the hook. Tared weight is displayed. It can set only one tare value. It will be shown with a minus value.
•
Press
to change between gross weight and net weight.
CLEARING TARE
•
To clear the tare value, remove the load from the hook.
•
Press
key. Zero is displayed, the
5.4 SELECT WEIGHING UNITS
•
Load the weight on the hook. Example: display show 0.8 KG
•
Hold
key for 3 seconds in normal weighing mode.
•
The weight will be convert to t unit ,the indicator of left side display will appear. Example: display show 0.0008 T
•
Hold
key again to back to kilogram mode.
5.5 OVERLOAD WARNING
Please do not add item that is over the maximum capacity. When reading --OL--, remove the item on the hook to avoid damage to the
load cell.
5.6 SLEEP MODE
•
Press
key to enter sleep mode in normal weighing mode, the display only show sleep indicator when in sleep mode;
•
Press
key again ,display will be back to normal weighing mode.
key. Display will be show the scale version and will be starting self checking.
key again.
key and therefore ensure that the weighing starts at zero.
button so that with subsequent weighing the net weight of the object being
indicator will be on.
indicator off ,tare weight is cleared.
USERS GUIDE SMC
EN