BONFIGLIOLI Vectron ACTIVE CUBE Serie Guia De Inicio Rapido página 75

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

8.3
Sizes 3 and 4 ACU 201 (4.0 up to 9.2 kW, 230 V)
Type
ACU 201
Size
Output Motorseitig
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-term overload current (1 s)
Output voltage
Protection
Rotary field frequency
Switching Frequency
Output, braking resistor
Min. Brake resistance
Recommended Brake resistance
(U
= 385 V)
dBC
Input, mains side
3)
Mains current
3ph
1ph/N; 2ph
Mains voltage
Mains frequency
Fuse 3ph
1ph/N; 2ph
Mechanical
Dimensions
Weight approx.
Ingress protection rating
Connection terminal
Form of assembly
Ambient conditions
Energy dissipation
(2 kHz Switching Frequency)
Coolant temperature
Storage temperature
Transport temperature
Relative humidity
If required by the customer, the switching frequency may be increased if the output current is reduced at the
same time. Comply with the applicable standards and regulations for this operating point.
6)
Output current
Frequency inverter nominal power
4.0 kW
4)
5.5 kW
4)
7.5 kW
4)
9.2 kW
1)
Three-phase connection requires a commutating choke.
2)
One- and two-phase connection requires a commutating choke.
3)
Mains current with relative mains impedance ≥ 1% (see chapter "Electrical installation")
4)
Three-phase connection permissible only.
5)
Reduction of switching frequency in thermal limit range
6)
Maximum current in continuous operation
7)
Device for single-phase mains connection is not included in the product catalog. However, it is available upon
request.
02/15
-18
P
kW
4.0
I
A
18.0
I
A
26.3
I
A
33.0
U
V
Maximum input voltage, three-phase
-
-
f
Hz
0 ... 1000, depending on switching frequency
f
kHz
R
Ω
24
R
Ω
30
18
I
A
2) 7)
28
U
V
f
Hz
25
I
A
35
HxWxD mm
250x100x200
m
kg
3.0
-
-
2
A
mm
0.2 ... 6
-
-
P
W
200
T
°C
n
T
°C
L
T
°C
T
-
%
Switching Frequency
2 kHz
4 kHz
2)
2)
18.0 A
18.0 A
1), 5)
1)
23.0 A
22.7 A
1)
1)
32.0 A
32.0 A
1)
1), 5)
40.0 A
38.3 A
Quick Start Guide ACU
-19
-21
3
4)
4)
5.5
7.5
22.0
32.0
30.3
44.5
33.0
64.0
Short circuit / earth fault proof
2, 4, 8, 12, 16
24
12
24
16
1)
1)
20
28.2
4)
4)
-
-
184 ... 264
45 ... 66
25
35
4)
4)
-
-
250x125x200
IP20 (EN60529)
0.2 ... 16
vertical
225
310
0 ... 40 (3K3 DIN IEC 721-3-3)
-25 ... 55
-25 ... 70
15 ... 85; not condensing
8 kHz
12 kHz
2)
2)
18.0 A
15.1 A
1), 5)
5)
22.0 A
18.5 A
1)
1)
32.0 A
26.9 A
1), 5)
1), 5)
35.0 A
29.4 A
-22
4
4)
9.2
35.0
51.5
64.0
12
12
1)
35.6
4)
-
50
4)
-
3.7
420
16 kHz
12.2 A
5)
15.0 A
21.8 A
5)
23.8 A
75