6

Instructions for operation

Caution
In order to avoid damage due to uncushioned move-
ment into the end position:
– carry out commissioning again if the fixed stops have
been adjusted or if components have been replaced.
– observe the maximum permitted mass load.
Control the drive with inputs P.01 to P.04 (see section 4).
When the position is reached, a 1-signal will be displayed
at the relevant output. If a mid-position is exceeded, the
relevant output will supply a 1-signal for 50 ms.
Change of direction is possible at any time during position-
ing.
Optimizing the positioning behaviour (if necessary)
S
Check the system structure and the compressed air
reservoir when there are fluctuations in pressure or
when the supply pressure has been modified.
S
Adapt the amplification or cushioning stage.
S
In order to reduce speed, fit restrictors in the exhaust
tubing of the MPYE-5-..., if necessary.
26