• Do not operate the unit when fatigued or under the influence of alcohol or drugs. Stay alert and watch what you are
doing.
• Know how to stop the unit and bleed pressure quickly. Be familiar with controls.
• Do not overreach or stand on an unstable support. Keep effective footing and balance at all
A PRESSURIZED ALUMINUM PARTS HAZARD
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing
such solvents in pressurized aluminum equipment. Such use can cause serious chemical
reaction and equipment rupture, and result in death, serious injury, and property damage.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
• Read all MSDS's to know the specific hazards of the fluids you are using.
• Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This protective equipment includes but is not limited to;
• Protective eye wear
• Clothing and respirator as recommended by the fluid and solvent manufacturer
• Gloves
• Hearing protection
:
GROUNDING
The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire
for the electrical current due to static build up or in the event of a short circuit.
• The sprayer power cord includes a grounding wire with an appropriate grounding contact.
• The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
• Do not modify plug. If it will not fit in outlet have grounded outlet installed by a qualified electrician. Do not
use an adapter.
Use only the correct pressure rated airless hose with static ground to reduce the risk of static discharge or injection.

POWER REQUIREMENTS

• 110V units required 100-120VAC 50/60Hz. 13A, 1 phase
• 220V units require 220-240 VAC, 50/60Hz, 7A, 1 phase

EXTENSION CORDS

• Use an extension cord with ground contact only. Should an extension cord be necessary use a 3 wire, 12 AWG
(2.5mm2) minimum. Do not exceed 300 ft 100 meters
times.