NaviTrack
Signal Strength..............Non-linear in function. (2000
is 10x higher than 1000, 3000
is 10x higher then 2000, etc.)
Operating Environment
Temperature................-4°F to 122°F (-20°C to 50°C)
Humidity ......................5% to 95% RH
Storage Temperature .....-4°F to 140°F (-20°C to 60°C)
Default Settings
The default settings for the locator are:
• Measured Depth units = Feet & Inches,
• Volume = 2 (two settings above mute),
• Backlight = Auto
• 512 Hz (Sonde) Default Mode
Optional Settings
The optional settings for the locator are:
• Measured Depth units = Meters,
• Volume = 0 (mute) to 5,
• Backlight = On, Off
• Mode: Active Line Trace, Passive Line Trace
Standard Equipment
Catalog
No.
Description
96967
NaviTrack II Locator
12543
Surface Markers and Clip
22388
Molded Carrying Case
—
Operator's Manual
—
Quick-Start Guide
Optional Equipment
Catalog
No.
Description
14818
NaviTrack Line Transmitter – 10 Watt
20168
NaviTrack Brick Transmitter – 5 Watt
20503
Inductive Clamp (4.75")
16728
Remote Transmitter (Sonde)
19793
Float Sonde (Package of 2)
12543
Surface Markers and Clip
4
®
II
(Downloadable @ www.navitrack.com)
(Downloadable @ www.navitrack.com)
Ridge Tool Company
Frequencies
Default Frequencies
Sonde ........................512Hz
Active Line Trace.......128Hz 1kHz, 8kHz, 33kHz,
262kHz (European: 93kHz)
Passive Line Trace ....60Hz (9th)
Optional Frequencies
Sonde ........................16Hz, 640Hz, 850Hz, 8kHz,
16kHz, 33kHz
Active Line Trace.......200kHz
Passive Line Trace ....50Hz (9th)
Nominal and Exact Frequency Values (NaviTrack II)
Sonde
16 Hz
512 Hz
640 Hz
850 Hz
8 kHz
16 kHz
33 kHz
Active Line
128 Hz
Trace
1 kHz
8 kHz
33 kHz
200 kHz
262 kHz
Passive Line
50 Hz
Trace
(9th harmonic)
60 Hz
(9th harmonic)
(European)
93 kHz
93 kHz -B
(See note on 93 kHz Frequencies on page 17.)
16
512
640
850
8192
16384
32768
128
1,024
8,192
32,768
200000
262,144
450
540 Hz
93,696.0
93,622.9