LIST OF ERROR CODES

Error code
Err01: Int_1 - Err02: Int_2
1
Err23 : Int_3
2
Err03: Fuse_NOK
3
Err04: T>Tmax
4
Err05: (+)(-)
5
Err06: U>__V
6
Err07: No_bat
7
Err08: U<__V
8
Err09: U>__V
9
Err10: U>2.0V
10
Err11: Time_Out
11
Err12: Q>___Ah
12
Err13: U<__V
13
Err14: Bat_UVP
14
Err15: U<__V
15
Err16: Bat_NOK
16
Err17: Recov_NOK
17
Err18: U>0V
24
24
101.24 CNT FV / 103.24 CNT FV
Applications
Initial configuration of the charger
Extensive features for garages
Simplified version for dealerships and demons-
tration vehicles
Professional of lithium battery
Forklift truck, electric pallet truck, stacker...
Full version
Meaning
Electronic problem
Defective charger
Output fuse out of order
Abnormal overheating
The polarity has been reversed on the
clamps
Overvoltage detected at the clamp
terminals
Battery not connected
Abnormally low battery voltage
Abnormally high battery voltage
Short-circuit detected during the
charge process
Triggering the time limit
Abnormally long charge
Tripping the overcharge protection
Abnormally low battery voltage when
checking the charge
Abnormally low battery voltage during
UVP Wake up
Battery too low
Battery out of order
Battery recovery failure
Presence of a voltage at the clamp
terminals when calibrating the cables
CHARGE MODE
Pb-CHARGE
Li-CHARGE
TRACTION
Contact the reseller
Have the fuse replaced by a qualified person
Contact the reseller
Connect the red clamp to the (+) and the black clamp to the (-)
of the battery.
Disconnect the clamps
Check that the battery is correctly connected to the charger
Check that the selected mode is compatible with the battery
voltage (e. g. : 6 V battery in 24 V mode)
Charge the battery via CHARGE mode
Battery to be replaced
Check that the selected mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
Check the assembly
Presence of a consumer on the battery disrupting the charge
Battery to be replaced
Presence of a consumer on the battery disrupting the charge
Battery to be replaced
Battery to be replaced
Presence of a short circuit, check the assembly
Battery to be replaced
Check that the selected mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
Battery to be replaced
Battery to be replaced
Battery to be replaced
Check the assembly