beyond the pumps designed capacity.
j. Observe all safety rules for the operation
of the engine as outlined in the relevant
Instruction Manual. Observe particularly the
refuelling procedures and safety rules.
SYMBOLS & LABELS
WARNING: Do not operate machine if
warning and/or instruction labels are missing
or damaged. Contact Evolution Power Tools
for relacement labels.
Symbol
Description
Read the Manual
Wear Safety
Goggles
Wear Ear Protection
Wear Dust Protection
Warning
CAUTION:
Hot exhaust
CAUTION
Do not touch
HOT SURFACE. DO NOT TOUCH.
CAUTION: This is a
UNLEADED
4 stroke engine. Fill
PETROL ONLY!
HIGHLY FLAMMABLE.
with unleaded petrol
only. Do not fill with
diesel oil.
Allow motor to cool
before opening the
fuel cap.
The vapour is
extremely flammable
and may ignite on
contact with a hot
surface or flames.
122
®
DWP1000 WATER PUMP SPECIFICATION
Inlet & Outlet Diameter:
------------------------------------------------------------
Pump Lift:
------------------------------------------------------------
Suction Height:
------------------------------------------------------------
Flow Rate:
------------------------------------------------------------
Optional Accessories:
------------------------------------------------------------
Weight:
Note: The Evo-System Engine Driven Water
Pump is designed for pumping water. It will
also pump water containing small solids in
suspension (max grain structure 8mm).
It is not designed to pump slurry, sludge,
sand or mud. The pump is fitted with an
open impellor. A suction filter should always
be used on the inlet hose to ensure that
large stones or debris etc are not sucked up
into the pump body. Damage can result if
large particles are drawn into the pump body.
www.evolutionbuild.com
75mm
28 metres
8 metres
1000 Litres/min
Suction Hose (Rigid)
Discharge Hose (Lay Flat)
Inlet Strainer
10.7kg