5
PREPARING THE PLACE OF
INSTALLATION
5.1
ASSEMBLY DIAGRAM
(Fig. 5.1)
A) For proper installation, the smoke ducting between
the fireplace and the flue must have all joints sealed.
B) Rear external air intake, ensure a minimum distance of
5 cm between cladding and combustion air intake pipe.
C) UNI standards require the installation of a heat
recovery grille as close as possible to the ceiling.
D) Counter-hood and fireproof load-bearing structure
E) Cladding in ceramic fibre or rock wool with external
aluminium foil
F)
Protect any wooden parts with fireproof material.
G) Min distance. 1 cm between cladding and fireplace
stove.
H) The cladding must be made of fireproof material.
Fig. 5.1.1 The product manual indicates the minimum
distances expressed in cm that must be respected when
positioning the fireplace with respect to combustible
materials and objects.
Provide a technical space accessible for possible
maintenance.
5.2
SAFETY PRECAUTIONS
The responsibility of the works carried out in the area where
the fireplace will be installed falls, and remains, on the
user; the latter is also entrusted with the execution of the
inspections related to the installation solutions proposed.
Any wooden beam of the cladding, or any finish in
combustible material must be adequately insulated (and in
any case placed outside the irradiation zone of the fire box).
The user must comply with all the local, national and
European safety regulations.
The appliance must be installed on floors with adequate
load bearing capacity.
If the floor is not of sufficient load-bearing capacity, it is
advisable to use a load distribution plate of adequate
dimensions.
The fireplace assembly and disassembly operations are
reserved for specialist technicians only.
Users should always use our assistance service for
requests for qualified technicians.
In the case other technicians are involved, it is
recommended to verify their actual abilities.
Before starting the installation or disassembly of the
fireplace, the installer must comply with the safety
precautions required by law and in particular:
1.
must not operate in adverse conditions;
2.
must operate in perfect psychophysical conditions
and must check that the personal protective
equipment, are intact and functioning perfectly;
3.
must wear safety gloves;
4.
must wear safety shoes;
5.
must ensure that the area affected by the phases of
assembly and disassembly is free from obstacles.
B
Z
MINIMUM DISTANCE FROM COMBUSTIBLE MATERIALS
Y2
X1
X1
40
X2
40
Y1
150
Y2
10
Z
100
29
C
A
E
D
F
G
H
Fig. 5.1
X2
Y1
40
40
40
40
150
150
10
10
100
100
Fig. 5.1.1