Air intakes with 680 m³/h ventilation kit.
In addition to the combustion air intake ("C" - Fig. 5.4.4a)
it is necessary to create the following fan air intakes:
: ambient air recovery (inside the room) to the heating
circuit fan, located on the side of the cladding (Ø15cm)
with grille.
: ambient air recovery (connected as (
or alternatively connected to an adjacent room (except
for kitchen, bathroom, bedroom) (Ø 15cm) with grille
(Fig. 5.4.4b).
In relation to the solution adopted, during the dry
installation test, it is advisable to mark the position of the
air inlets both on the external wall and on the cladding.
The fan air intakes can be equipped with an
adjustable closing damper, and must be equipped
with an anti-insect mesh grille.
Any filters or grilles must be cleaned periodically,
removing any fluff which may cause blockages.
5.5

AIR CIRCULATION

There are three possible solutions to hot air circulation:
1.
STANDARD NATURAL CIRCULATION
(supplied with the machine)
2.
HOOD NATURAL CIRCULATION
(with the Natural ventilation with hood kit)
3.
HOOD FORCED CIRCULATION
With the Centrifugal fan with adjustment unit kit and
Ventilation with hood kit.
(Fig. 5.4.4a)),
32
>50 cm
C
A
C
Fig. 5.4.3a
10
>50
>35
Fig. 5.4.3b
B
Fig. 5.4.4a
D
Fig. 5.4.4b